 ASDX Series
Signal conditioned pressure transducers
FEATURES
* 0...1 to 0...100 psi, 0...1 to 0...100 psi * Absolute, gage or differential pressure * 0.5...4.5 V ratiometric output * Precision ASIC conditioning * Temperature compensated
GENERAL DESCRIPTION
The amplified ASDX offers a high level (4.0 V span) output on a very costeffective basis. This family is fully calibrated and temperature compensated using an on-board ASIC. These sensors are intended for use with non-corrosive, non-ionic working fluids such as air and dry gases. Devices are available to measure absolute, differential, and gage pressures from 1 to 100 psi. The absolute devices have an internal vacuum reference and an output voltage proportional to absolute pressure. Differential devices allow application of pressure to either side of the sensing diaphragm and can be used for gage or differential measurements.
APPLICATIONS
* Medical instrumentation * Barometry * HVAC controls * Pneumatic controls
All ASDX devices are accurate to within 2.0 %FSS. The devices are characterized for operation from a single 5 V supply. The sensor is designed and manufactured according to standards laid down in ISO 9001.
ELECTRICAL CONNECTION
N/C
567
1
+Vs
Note:
Capacitor 220 nF required between +Vs and GND and 15 nF between Vout and GND. It is important to place the capacitors as close to the pins as possible! Pins 4, 5, 6, 7 and 8 are internal device connections and should not be connected for any reason!
ASDX
2
Vout 15 nF
220 nF
3 84
GND
N/C
February 2009 / 530
1/6
www.sensortechnics.com
ASDX Series
Signal conditioned pressure transducers
PRESSURE SENSOR CHARACTERISTICS
Maximum ratings Supply voltage VS Output current Sink Source Lead temperature (2 - 4 sec.) 4.75 V to 5.25 VDC max. 6.50 VDC 2 mA 2 mA 250 C Environmental specifications Temperature ranges Compensated Operating Storage Vibration: Shock:
0 to +85 C -20 to +105 C -40 to +125 C 10 g at 20 - 2000 Hz 100 g for 11 ms
Caution!
The sensor is not reverse polarity protected. Incorrect applications of excitation voltage or ground to the wrong pin can cause electrical failure. Application of supply voltage above the maximum can cause electrical failure.
PRESSURE RANGES SPECIFICATIONS
(VS = 5.0 VDC, TA = 25C)
Part number
A S D X 015A 24R A S D X 030A 24R A S D X 100A 24R ASDX001G24R / D44R ASDX005G24R / D44R ASDX015G24R / D44R ASDX030G24R / D44R ASDX100G24R / D44R A S D X 001D 44D A S D X 005D 44D A S D X 015D 44D A S D X 030D 44D A S D X 100D 44D
Pressure range
0 to 15 0 to 30 0 to 100 0 to 1 0 to 5 0 to 15 0 to 30 0 to 100 psi(g,d) 0 to 1 0 to 5 0 to 15 0 to 30 0 to 100 psi(a)
Burst pressure1
30 60 150 5 20 30 60 150 psi(g,d) 5 20 30 60 150 psi(a)
Sensitivity (typ.)
0.267 0.133 0.040 4.00 0.80 0.267 0.133 0.040 2.00 0.40 0.133 0.067 0.020 V/psi
February 2009 / 530
2/6
www.sensortechnics.com
ASDX Series
Signal conditioned pressure transducers
PERFORMANCE CHARACTERISTICS
0.5 to 4.5 V ratiometric output (VS = 5.0 VDC, TA = 25C)
All ASDX...A24R, ...G24R, ...D44R
Characteristics
Zero pressure offset Full scale span (FSS)2 Full scale output Total accuracy (0 to 85C)3 Sample rate Response delay4 Quantization step5 Current consumption
Min.
0.42
Typ.
0.50 4.00
Max.
0.58
Units
V 4.58 2.0 %FSS Hz 14.11 ms mV mA
4.42
4.50
100 2.73 3 6
All ASDX...D44D
Characteristics
Zero pressure offset Full scale span (FSS)2 Output at max. specified pressure at min. specified pressure Total accuracy (0 to 85C)3 Sample rate Response delay4 Quantization step5 Current consumption
Min.
2.42
Typ.
2.50 4.00
Max.
2.58
Units
V 4.42 0.42 4.50 0.50 4.58 0.58 2.0 100 2.73 3 6 14.11 %FSS Hz ms mV mA
February 2009 / 530
3/6
www.sensortechnics.com
ASDX Series
Signal conditioned pressure transducers
TOTAL ACCURACY (-20 to +105C)
Total accuracy (%FSS)
3.0 2.0 1.0 0 -1.0 -2.0 -3.0 -20 0 20 40 60 85 105
Temperature (C)
Specification notes:
1. If maximum burst pressure is exceeded, even momentarily, the package may leak or burst, or the pressure sensing die may fracture. 2. Full Scale Span (FSS) is the algebraic difference between the output signal for the highest and lowest specified pressure. Span is ratiometric to the supply voltage. 3. Total accuracy is the combined error from offset and span calibration, linearity, pressure hysteresis, and temperature effects. Linearity is the measured deviation based on a straight line. Hysteresis is the maximum output difference at any point within the operating pressure range for increasing and decreasing pressure. Calibration errors include the deviation of offset and full scale from nominal values. 4. Delay time between sampling and signal change at the output. 5. The smallest change in the output voltage, given any change in pressure.
February 2009 / 530
4/6
www.sensortechnics.com
ASDX Series
Signal conditioned pressure transducers
PHYSICAL DIMENSIONS
D4 package
1.27 typ (0.050 typ) 16.89 (0.665)
7.87 typ (0.310 typ) 13.97 (0.550) 3.63 (0.143) 8.13 8.89 (0.350) (0.320) 1.78 (0.070) 16.64 0.64 (0.655 0.025) 2.29 (0.090)
High pressure port Low pressure port
3.38 (0.133) 8.26 typ (.325 typ)
0.51 typ (0.02 typ) 2.54 typ (0.100 typ) 4.5 (0.177)
G2 package
6.99 (0.275) 3.15 (0.124) 1.27 typ (0.050 typ) 13.97 (0.550) 2 typ 16.89 (0.665)
4.9 (0.193) 2.29 typ (0.090 typ) 2.79 typ (0.11 typ)
1.19 typ (0.047 typ)
8.89 5.08 (0.350) (0.200) 16.64 0.64 (0.655 0.025)
0.51 typ (0.02 typ) 4.5 (0.177) 2.54 typ (0.100 typ)
A2 package
1.27 typ (0.050 typ) 13.97 (0.550) 2.29 typ (0.090 typ) 8.0 typ (0.315 typ) 8.89 (0.350) 0.51 typ (0.02 typ) 2.54 typ (0.100 typ) 16.89 (0.665) 8.46 (0.333)
16.64 0.64 (0.655 0.025)
4.5 (0.177)
third angle projection
February 2009 / 530
dimensions in mm (inches)
5/6
www.sensortechnics.com
ASDX Series
Signal conditioned pressure transducers
ELECTRICAL CONNECTIONS
ASDX...D4...
Vs (pin 1) identifier
N/C N/C N/C N/C +Vs Vout GND N/C
ASDX...G24R
Vs (pin 1) identifier
+Vs Vout GND N/C
N/C N/C N/C N/C
ASDX...A24R
Vs (pin 1) identifier
Note: Pins 4, 5, 6, 7 and 8 are internal device connections and should not be connected for any reason!
N/C N/C N/C N/C
+Vs Vout GND N/C
ORDERING INFORMATION
Pressure range
0 to 1 psi 0 to 5 psi 0 to 15 psi 0 to 30 psi 0 to 100 psi 0 to 1 psi 0 to 5 psi 0 to 15 psi 0 to 30 psi 0 to 100 psi A S D X 015A 24R A S D X 030A 24R A S D X 100A 24R
Absolute
Gage
ASDX001G24R ASDX005G24R ASDX015G24R ASDX030G24R ASDX100G24R
Differential/Gage
A S D X 001D 44R A S D X 005D 44R A S D X 015D 44R A S D X 030D 44R A S D X 100D 44R A S D X 001D 44D A S D X 005D 44D A S D X 015D 44D A S D X 030D 44D A S D X 100D 44D
Other pressure ranges or calibrations are available on request
SenSym and Sensortechnics reserve the right to make changes to any products herein. SenSym and Sensortechnics do not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. February 2009 / 530 6/6
www.sensortechnics.com


▲Up To Search▲   

 
Price & Availability of ASDX015A24R

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X